Colortronic CTT 60 Betriebsanleitung

Stöbern Sie online oder laden Sie Betriebsanleitung nach Luftentfeuchter Colortronic CTT 60 herunter. Colortronic CTT 60 Operating instructions Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - Adsorption Dryer

Operating InstructionsAdsorption DryerCTT 300Colortronic GmbH

Seite 2

1.3. For your safety•The operator of this machine must be at least 16 years old.•Read these operating instructions carefully before the initial start-

Seite 3

•The local regulations and requirements pertaining to the equipment must beobserved.•The ”5 safety rules” as provided in DIN VDE 0105, Section 1, must

Seite 4 - Table of contents

•Repair work may be carried out only by trained staff.Danger of accidents!•Never operate the equipment when it is partly dismantled.Danger! Limbs may

Seite 5

•The air filters should only be cleaned/replaced when the the main switch is off andthe blower has stopped.This avoids injury and damage to equipment!

Seite 6

•Take care that the device is not standing on the mains cable.This will prevent danger to people and material!•Please note that the drying cells, dryi

Seite 7 - 1. Safety instructions

1.4. For the safety of the devices•Never change settings without carefully assessing the consequences.•Use only original Colortronic spare parts.•Obse

Seite 8

•Note that too large amounts taken from the drying hopper lead to insufficientdrying of the material.•Close the air stop valves of drying hoppers whic

Seite 9

2. Assembly instructionsVersion: 64.10-0128GB02 10/97»These installation instructions are intended for persons withskills in electrical and mechanical

Seite 10

FInstall the equipment such that all parts are easily accessible; this facilitates maintenance and repair work.Dehumidified air dryerAssembly instruct

Seite 11

2.1. TransportOnly use for transport of the dryer a suitable hoist (e. g. a fork lift truck or aworkshop crane).»Please ensure adequate carrying capac

Seite 12

Technical service:Service departmentTelephone: (0 61 75) 7 92-2 22Telefax: (0 61 75) 7 92-1 19Email [email protected] parts departmentT

Seite 13

with a workshop craneCheck if the eyelets are installed on the dryer housing.If this condition is met, fasten the transport cables to the eyelets.If t

Seite 14

2.2. Set-upA special foundation is not required for installation. The dryer must be installed on a level surface, and may not be exposed toexcessive h

Seite 15

2.4. Connection of the return air cooler (optional)FA return air cooler is generally required in cases in which thereturn air temperature is over 65°

Seite 16

2.5. Electrical connection»Observe the rules of the local electricity board.Check that the supply voltage and the power frequency are inaccordance wit

Seite 17 - 2. Assembly instructions

3. Functional descriptionVersion: 64.10-0145GB01 03/98»This functional description is intended for all operatingpersonnel of the equipment.Prerequisit

Seite 18 - Assembly instructions 2-2

3.1. DryerThe dryer operates with dehumidified air, i.e. the air is not only heated but alsodehumidified before flowing into the drying hopper. This p

Seite 19

3.2. Drying hopper (optional)The material is dried in the drying hopper. The dehumidified air (2) is forcedthrough the material in the hopper, collect

Seite 20

3.3. Return air cooler (optional)FA return air cooler is generally required in cases in which thereturn air temperature is over 65° C.A return air coo

Seite 21

3.4. Hopper heaters (optional)If differing drying temperatures are required in the different drying hoppers,hopper heaters must be installed on the dr

Seite 22

3.6. Connection to a pneumatic conveying system (optional)The dryer operates most effectively in conjunction with a pneumatic conveyingsystem. This co

Seite 23

Colortronic GmbH retains all rights to change the information in these operatinginstructions at any time without notice.We assume no liability for any

Seite 24 - 3. Functional description

4. Start-upVersion: 64.10-0130GB04 03/98»This chapter is directed at the operators of the equipment.This chapter assumes general skills in dealing wit

Seite 25

4.1. Control systemThe control system is switched on at the main switch. The control system isoperated via a ”selection window” and the keyboard of th

Seite 26

4.1.1. Key assignmentF1-key: Leads to the table of contents.ENTER-key: Confirms the entries.ESC-key: Goes back one step in the menu.ACK-key: Activates

Seite 27

4.1.2. Flow chart1 Indicator lamp2 Valve system3 Drying chamber4 Drying blower5 Return air filter6 Drying hopper7 Drying heater8 Regeneration heater9

Seite 28

4.2. Switching on the dryerSwitch on the system by means of the main switch.&The control system carries through a self-test; after that, thename o

Seite 29

4.3. Initial operation&Before initial operation, all control data should be set back.»This work may be carried through only by qualified personnel

Seite 30 - 4. Start-up

&All control data are set back to the standard settings.Set the on/off switch (4) at position ”1".Insert the battery into the battery compart

Seite 31

4.5. Basic parametersPress the ”F1"-key.4.5.1. Turning the devices on/offSelect ” Main menu ”.Acknowledge with the ENTER-key.orPress the ”F2” -k

Seite 32

Return air cooler on/off (optional)“on” = operation with return air cooler,“off” = operation without return air coolerAcknowledge with the ENTER-key.H

Seite 33

4.5.2. Entering dryer valuesSelect ”Dryer” .Acknowledge with the ENTER-key.orPress the ”F3” -key.Drying Heater Target (optional)Enter the drying te

Seite 34

Table of contents1. Safety instructions (Version: 64.10-0127GB01 10/97) ... 1-11.1. Warnings and symbols ...

Seite 35

Return air cooler Target (optional)Enter the max. permissible return air temperature (65° C max.). Highertemperatures are not allowed.Acknowledge wit

Seite 36

Dew point max.Enter the maximum permissible (worst allowed) dew point temperature (-35 to 28° C).Acknowledge with the ENTER-key.Dew point Act.The curr

Seite 37

4.5.3. Entering hopper valuesSelect ”Hopper” .Acknowledge with the ENTER-key.orPress the ”F4” -key.Hopper entry X Target(X = number of the drying ho

Seite 38

Granules Xdesired: _ % = _ °C(X = number of the drying hopper)Enter the material temperature at which the flap (optional) on the drying hopper Xshould

Seite 39

Granules Xdwelling time: _ minThe dwelling time of the material within the drying hopper X is displayed inminutes.FObserve the indicated dwelling time

Seite 40

4.5.4. Observing processing statusSelect ”Status” .Acknowledge with the ENTER-key.orPress the ”K1” -key.&The current operation status of individ

Seite 41

4.5.5. Setting date and time&This function is password protected.Press the “K3" -key.Enter the password if requested.DatePress the SHIFT key

Seite 42

4.5.6. Viewing/changing language and contrast&This function is password protected.Press the “K4" -key.Enter the password if requested.Contra

Seite 43

4.5.7. Changing parametersSelect ”Parameters” .Acknowledge with the ENTER-key.orPress the SHIFT -key and the ”K1” -key.FThe values in this menu may

Seite 44

4.5.8. Setting the timerSelect ”Timer” .Acknowledge with the ENTER-key.orPress the SHIFT -key and the ”F1” -key.XX ON 00:00 OFF 00:00 (XX

Seite 45

4. Start-up (Version: 64.10-0130GB04 03/98) ... 4-14.1. Control system ... 4-24.1.1. Key assi

Seite 46

4.6. Recipes (optional)Select “ Recipes ”.Confirm with the ENTER-key.orPress the keys “ Shift ” and “ F3 “.Hopper no. X (X = number of the drying hop

Seite 47

4.6.1. Editing recipesEditPress the “F2"-key.Recipe range X (X = 1 - 4)Select the recipe range.Confirm with the ENTER-key.&99 recipes can be

Seite 48

4.6.1.1. Storing the recipeNo.Enter a recipe number.Confirm with the ENTER-key.NameEnter a name for the recipe.Confirm with the ENTER-key.Store data r

Seite 49

4.6.2. Activating the recipePress the keys “ Shift ” and “ F3 “.Hopper no. X (X = number of the drying hopper)Enter the number of the drying hopper w

Seite 50

DestinationEnter “0" if you want to activate the recipe.Confirm with the ENTER-key.&Enter a number between 1 and 99 if you want to store ther

Seite 51

4.6.3. Printing recipesFMake sure that a printer (optional) has been connected andis switched on.Press the keys “ Shift ” and “ F3 “.Press the “↓” ke

Seite 52

4.7. Starting continuous operationWhen you have carried through all basic settings, you can start with continuousoperation.&For initial operation:

Seite 53

4.8. Alarm Messages&Alarm messages are displayed in plain language on thescreen of the operator device.The display of alarm messages in the operat

Seite 54

ViewPress the ”F2" -key.All alarm messages with their numbers (see Texts), date, time and thesupplement ”K”, ”G”, or ”Q” are displayed.&”K”

Seite 55

NumberPress the ”F2" -key.Total messagesThe number of all alarm messages is displayed.Waiting messagesThe number of current alarm messages is di

Seite 56

5. Maintenance (Version: 64.10-0146GB01 03/98) ... 5-15.1. Maintenance intervals ... 5-35.2. Cleaning/re

Seite 57

OverflowPress the ”F2" -key.&If there are more current alarm messages than can be saved, a warning message (= residual buffer reached) may b

Seite 58

TextPress the ”F3" -key.All possible alarm messages are displayed with their numbers (see Viewing).For viewing the possible alarm messages, pres

Seite 59

Vacuum Regeneration BlowerThe regeneration blower does not produce sufficient pressure.Check the blower.Vacuum sensor defective.The Safety Switch Dryi

Seite 60

The Safety Switch Regeneration Heater Has Been ActuatedCheck the heater.Check the fuses.Short circuit check of the heater.Error Bypass FlapThe bypass

Seite 61

Excess Temperature Drying HeaterThe drying temperature is too high.Check the safety temperature limiter.Colortronic Service.Insufficient Temperature D

Seite 62

Safety Switch Heater Hopper X(X = number of the drying hopper)Check the heater.Check the fuses.Short circuit check of the heater.Temperature Measureme

Seite 63

4.9. Viewing system runtimeSelect ”System runtime” .Acknowledge with the ENTER-key.orPress the SHIFT -key and the ”F2” -key.System runtimeXX h YY

Seite 64

4.10. Switching the dryer offSelect ”Main menu”.Acknowledge with the ENTER-key.orPress the ”F2” -key.Select ” Dryer off ”.Acknowledge with the ENTER

Seite 65

5. MaintenanceVersion: 64.10-0146GB01 03/98»This chapter is intended for persons with skills in electrical andmechanical areas due to their training,

Seite 66

LDisconnect the equipment from mains supply before startingmaintenance procedures to ensure that it cannot beswitched on unintentionally.Depressurize

Seite 67

1. Safety instructionsVersion: 64.10-0127GB01 10/97»These safety instructions apply to all persons within the range of action of the equipment.Please

Seite 68 - 5. Maintenance

5.1. Maintenance intervalsDaily: Check warning signs on equipment for good legibility and completenessClean return air filter and housing (depending

Seite 69

5.2. Cleaning/renewing the air filtersPress the ”F2” -key.Select ” Dryer off ”.Acknowledge with the ENTER-key.LWait until the blowers have stopped tu

Seite 70

Return air filterLoosen the securing nut on the return airfilter housing and remove the housing lid.Remove the return air filter.Clean the return air

Seite 71

Regeneration air filterLoosen the securing nut on lid of the regeneration air filter.Remove the lid and regeneration air filter housing.Loosen the two

Seite 72

Filter of the electrical cabinetRemove the lid of the filter.Remove the filter mat.Blow through the filter mat with compressed air from inside to outs

Seite 73

5.3. Tensioning the V-beltsPress the ”F2” -key.Select ” Dryer off ”.Acknowledge with the ENTER-key.LWait until the blowers have stopped turning. Swit

Seite 74

&Order number V-belts blower ”regeneration heater”: ID 93741blower ”drying heater”: ID 83993CTT 300Maintenance 5-9CTT 300blower ”regeneration hea

Seite 75

Blower ”regeneration heater”Remove the protective grid of the blower (position 3).Loosen the nut (position 1).Loosen and remove the screw (position 2)

Seite 76 - Maintenance 5-9

Blower ”drying heater”Remove the protective grid of the blower (position 3).Loosen the nut (position 1).Loosen and remove the screw (position 2).Slide

Seite 77

5.4. Disposing of the drying agentEnsure that drying cells are exchanged by Colortronic or refilled only whenempty.Drying agents must be disposed of i

Seite 78

1.1. Warnings and symbolsThe following warnings and symbols are used in these operating instructions:»This symbol indicates danger to life! Fatal or s

Seite 79

5.5. Changing the battery of the control system»This work may be carried through only by qualified personneltrained in the field of electrical enginee

Seite 80

Insert the new battery into the battery compartment.FNote the polarity on the back wall of the batterycompartment.Make sure that the plastic band is l

Seite 81

6. Technical DataVersion: 64.10-0147GB01 03/98Volume of dehumidified air: ... 300 m3 /hOperation voltage: ...

Seite 82 - 6. Technical Data

Electrical cabinet:Width*: ... 700 mmHeight*: ... 1800 mm

Seite 83

Dimension sheet64.10-0132GB01 06/98CTT 300Technical Data 6-3101078O198OPEDimensions in mm. Specifications may be subject to alterations.

Seite 84 - Technical Data 6-3

7. Spare parts listVersion: 64.10-0148GB01 03/98»This spare parts list is intended to be used only by trainedpersonnel.Other persons are not permitte

Seite 85 - 7. Spare parts list

CTT 30019264 Drying heater (complete)95828 Tubular heating element 230 V, 3 kW85276 STB (drying) 160-250 °C86363 Spindle motor 24 V19267 Regeneration

Seite 86

86371 Multiplier Pt 100 (3 m)89846 Multiplier Pt 100 (6 m)93303 Multiplier PT 100 (9 m)86387 Multiplier PT 100 (12 m)95819 Pull-button85682 Micro-swit

Seite 87

8. Electrical manualVersion: 64.10-0133GB01 10/97»This electrical manual is intended to be used only by Colortronicservice personnel and trained perso

Seite 88 - 8. Electrical manual

9. AccessoriesVersion: 64.10-0134GB01 10/97Dehumidified air dryerAccessories 9-1

Seite 89 - 9. Accessories

1.2. Explanations and informationVarious terms and designations are used in these operating instructions toensure clarity. Therefore please note that

Kommentare zu diesen Handbüchern

Keine Kommentare